KDGC1100S




520S

Ratings

Standby Power

kVA

1375

kW

1100

Prime  Power

kVA

1250

kW

1000

Voltage type

50Hz,380/220V, 3 phases and 4 wires


Perfo
rmance Data

Engine Brand & Model

Cummins KTA50-G3

Alternator Brand & Model

Leroy Somer LSA50.2M6

Control System

Deepsea DSE6120

Standard Noise Level@7m (Soundproof Sets)

75 dBA

Circuit Breaker Type

3 Poles MCCB

Frequency & Phase

50Hz, 3Phases + 4Wires

Engine Speed (RPM)

1500

Fuel Consumption (L/hr)

100% Load

261

75% Load

199

50% Load

139

25% Load

76

 

Dimensions and Weights

Content

Open type

Soundproof Sets

Dimensions: (mm)

L

4950

6059

W

2080

2438

H

2630

2591

Weights (kg)

9800

11800


Engine Brand & Model: Cummins KTA50-G3

Standard Cummins Engine Data

No. of Cylinders

12 V

Gross Engine Power(kW)

Prime

1227

Cycle

4 Stroke

Standby

1380

Bore / Stroke

159mm / 159 mm

Compression Ratio

13.9:1

Induction

Turbocharged and Air-air cooled

Displacement (L)

50.3

Cooling Method

Charge Air Cooling

Governing Type

Electronic

Starting method

24V DC motor

Coolant capacity (L)

160.9

Lubricant Oil

15W40-CF4 or above grade

Lube System Capacity(L)

176.8


When engine is unable to start: 

No.Malfaunction and causesRemedy
5Speed governor system error
(1)The electric power source of speed governor 
is cut down or connected oppositely
(2)Diasu structure drive link is locked
(3)Restriction value of the electric current of speed
 governor is too high
(1)Check the electric power source and connecting wire
(2)Reinstall and adjust it
(3)Properly increase the restriction value of the electric 
current (direction of inverse hour)
6Iginition normally but unable to catch fire
(1)Over abrasion of piston ring or cylinder sleeve
(2)Steam leakage of valve
(3)Abnormal fuel gas
(1)Replace the piston ring, and replace the cylinder 
sleeve according its abrasion circumstances
(2)Check the valve and repair and adjust it
(3)Check and use nomal fuel gas
7Blockage of fuel conveying speed governor 
make pipe line
Clear or replace it
8Over low ambient temperature; 
Long time ignition for starting
According to the actual ambient temperature, 
adopt correspnd low temperature starting measure.