650 KVA Standby Diesel Generator

650 KVA Standby Diesel Generator

Diesel generator set from 18 to 1320 kW; Cummins engine; Leroy somer or Stamford alternator; Factory price and factory outlet; CE/ISO and BV/TUV/SGS verified; OEM and ODM manufacturer; ...

Send InquiryChat Now
Product Details








KDGC520S   50Hz


520S


Ratings

Standby Power

kVA

650

kW

520

Prime  Power

kVA

575

kW

460

Voltage type

50Hz,400/230V, 3 phases and 4 wires

 

Performance Data

Engine Brand & Model

Cummins KTA19-G8

Alternator Brand & Model

LSA47.2L9

Control System 

Deepsea DSE6120

Standard Noise Level@7m (Soundproof Sets)

80 dBA

Circuit Breaker Type

3 Poles MCCB

Frequency & Phase

50Hz, 3Phases + 4Wires

Engine Speed (RPM)

1500

Fuel Consumption (L/hr)

100% Load

127

75% Load

95

50% Load

69

25% Load

35

 


Dimensions and Weights

Content

Open type

Soundproof Sets

Dimensions: (mm)

L

3550

5000

W

1530

1800

H

2080

2450

Weights (kg)

4183

5800

 


Engine Brand & Model: Cummins KTA19-G8

Standard Cummins Engine Data

No. of Cylinders

6 in line type

Gross Engine Power(kW)

Prime

/

Cycle

4 Stroke

Standby

575

Bore / Stroke

159mm /159mm

Compression Ratio

13.9:1

Induction

turbo-charged aftercooled

Displacement (L)

18.9

Cooling Method

Radiator fan cooling

Governing Type

Electronic

Starting method

24V DC motor

Coolant capacity, including radiator (L)

30

Lubricant Oil

15W40-CF4 or above grade

Lube System Capacity(L)

50

 




How to clean the cooling system: 

◇Use eau douce to clean the cooling system;

◇If there is a drainage valve, close it or connect the coolant pipe;

Note: In order to avoid producing air pocket, and the speed of intake coolant could not be over 19 L/min.

◇Inject the mixture of water and cleaner into cooling system. Consult the manufacture 's direct, close the cover; 

◇Start the engine, running the genset without any load for 30 minites, and wait the coolant temperature reach to 82 ℃(180℉). 

◇Stop the engine, after it has been cold, loosen the cover of cooling system and depress its pressure. Take off the cover, open the drainage valve (if there is), or take off the coolant pipe at the bottom, so that the coolant can leak out from cooling system, and use eau douce to clean the cooling system, then close the valve or connect the coolant pipe.

How to add coolant: 

◇Inject the right coolant to the cooling system via the injector, but don't cover the injector.

◇Start the engine, and keep idle running for1 minute so as to discharge all the air among the gaps, and then stop it.

◇Check the coolant level and keep it equal the bottom of the injector.

◇Clean the cover of the injector, and check its gasket. If the gasket gets out of work, the cover needs to be replaced. If the gasket can work, please use right PRESSURE INSPETING TOOL to inspect the injector cover and check if it meets the required pressure marked on the cover. If it can't meet, please replace to new injector cover.

◇Start the engine, check the cooling system whether any leak occurred, and whether the runing and temperature on good condition.

Protective equipment: 

The safe and protective equipment must be installed when install gas generator set, to protect the personal and matterssafety. The protective panel should be installed for revolving parts or moving parts. The heat insulating equipment should be installed for high temperature parts to ensure the safety of operator.

 

Crankcase breather:

All engines are designed with crankcase breather and exhaust pipe to discharge the gas of crankcase, lower the pressure of crankcase. Please check if the installing position of crankcase breather and exhaust pipe are right or faulse before genset operation.

Cooling system clutch and connection:

When the engine is still operating or water temperature is still very high, please don't loosen the clutch. Because the pressure of cooling system is very high, if the clutch is loosen, high temperature water will be sprayed out and cause seriously scald. After the engine and water cool, heat exchanger, thermometer box and radiator clutch can be open. In order to ensure the person and genset safety, please change the problematic and aged pipes timely.

 


Hot Tags: 650 kva standby diesel generator, China, suppliers, manufacturers, factory