Ratings *Ratings at 0.8 power factor Performance Data * The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm 3 Dimensions and Weights Engine Brand & Model: HGNT14 Engine Data How to install, use and maintain battery: ◇Before installing, please check the...

Send Inquiry
Product Details


KDGH200-BG   50HZ1.jpg


Ratings

Rated  Power

kVA

250

kW

200

Voltage type

50Hz, 380/220V, 3 phases and 4 wires

*Ratings at 0.8 power factor


Performance Data

Engine Brand & Model

HGNT14

Alternator Brand & Model

LSA46.3S5/200KW

Control System

Deepsea DSE6120

Standard Noise Level@7m (Soundproof Sets)

75 dBA

Circuit Breaker Type

3 Poles MCCB

Frequency & Phase

50hz 3Phases + 4Wires

Engine Speed (RPM)

1500

Fuel Consumption (Nm3/hr) 100% Load

64.05

* The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm3


Dimensions and Weights

Content

Open type

Soundproof Sets

Dimensions: (mm)

L

3150

4200

W

1100

1500

H

1800

2250

Weights (kg)

2525

5025


Engine Brand & Model: HGNT14

Engine Data

No. of Cylinders

6  in-line

Engine power(KW)

240

Cycle

4 Stroke

Cylinder Type

Wet

Bore * Stroke (mm)

140 * 152

Compression Ratio

11:01

Induction

Turbocharged and Aftercooled

Displacement (L)

14

Cooling Method

Water cooled

Governing Type

Electronic

Starting method

24V DC motor

Coolant capacity, including radiator (L)

66.8

Lubricant Oil

15W40-CF4 or above grade

Oil pan capacity (L)

36


How to install, use and maintain battery: 

◇Before installing, please check the level of electrolyte in batteries. If it isn't up to the required, more electrolyte need to be filled in.

◇Don't hit the batteries, in order to avoid any leakage of electrolyte which may short the lifetime of batteries, even bring on short circuit inside of the battery and scrap it. 

◇Put batteries at the special position, and wipe antioxidant completely on the positive and negative pole of the battery, don't use lubricating grease.

◇If electric system can work well, the specific gravity of electrolyte will be nomal amount. Checking for once is needed per month for the level of electrolye, and fill it in when necessary and never use sulphuric acid.

◇Don't use the batteries to power the load, as the capacity of the batteries is only for genset itself.

Caution: When checking the electronic system: Too much electrolyte consumption. (means overload); Batteries can't up to named capacity and specific gravity reduce(means battery capacity is small); Always keep the batteries clean and dry outside, and never use gasoline as cleaner; If floating charger equipped, its normal working must be quaranteed anytime.


Engine fuel:

When the engine is started for three or more than three times or engine stop automatically suddenly, the gas valve should be turn off immediately, and then start the engine once again, discharge the unburned residual gas in engine. Otherwise it will cause explosion of residual gas inside engine in the situation of engine starting.


Cut off fuel:

All gensets are installed one reliable Gas Shut-off Valve, which is an urgent valve and can shut-off the gas fuel completely.The inlet pipe of some pressed fuel (natural gas or LPG) will be installed one manual controlling valve to shut-off the fuel, which can also shut-off the fuel supply in the urgent situation. 