Tel: +86-769-88996313

E-mail: sf@camda.cc

300 KW Biogas Generator

300 KW Biogas Generator

Ratings *Ratings at 0.8 power factor Performance Data * The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm 3 Dimensions and Weights Engine Brand & Model: HGKT38 Engine Data Gen-set Fastening and Shock-proof Devices: In general when manufacturing, a...

Send InquiryChat Now
Product Details


KDGH300-BG    50HZ300


Ratings

Rated  Power

kVA

375

kW

300

Voltage type

50Hz, 380/220V, 3 phases and 4 wires

*Ratings at 0.8 power factor


Performance Data

Engine Brand & Model

HGKT19

Alternator Brand & Model

LSA47.2VS2/300KW

Control System

Deepsea DSE6120

Standard Noise Level@7m (Soundproof Sets)

75 dBA

Circuit Breaker Type

3 Poles MCCB

Frequency & Phase

50hz 3Phases + 4Wires

Engine Speed (RPM)

1500

Fuel Consumption (Nm3/hr) 100% Load

86.19

* The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm3


Dimensions and Weights

Content

Open type

Soundproof Sets

Dimensions: (mm)

L

3500

5600

W

1250

2000

H

2020

2500

Weights (kg)

3380

4985


Engine Brand & Model: HGKT38

Engine Data


No. of Cylinders

6 in-line

Engine power(KW)

341

Cycle

4 Stroke

Cylinder Type

Wet

Bore * Stroke (mm)

159 * 159

Compression Ratio

11.5:1

Induction

Turbocharged & Aftercooled

Displacement (L)

18.9

Cooling Method

Water cooled

Governing Type

Electronic

Starting method

24V DC motor

Coolant capacity, including radiator (L)

115

Lubricant Oil

15W40-CF4 or above grade

Oil pan capacity (L)

87



Gen-set Fastening and Shock-proof Devices:

In general when manufacturing, a Cushioning Pad has been installed on the rigid base of the generator set, and has proofread the engine and the alternator exactly. So only need to install the genset in a predetermined position, and put in standard level.

If the genset is not installed with shockproof pad, shockproof device will be needed when the genset is placed on the flat-panel; rubber cushion or steel shells can be used to decrease vibration, otherwise the genset will be damaged or have unsuitable shock.

If possible, the concrete foundation should tamp the below raw soil or backfilling concrete in advance, then form a 200mm layer of shock absorption with cement, asphalt, cinder mixed with water. It can prevent the shock of genset and the resonance of some of the plant.

WARNING: The inherent vibration rate should be more than two times of the engine speed. If it close to the engine speed, parts of the plant may have the possibility to make resonance.


Ventilation:

The running of the engine and operation of the alternator will spread heat all through the plant room and raise the temperature of the room, so ventilation is essential. It can control the plant room temperature effectively, and supply the generator with cool and fresh air.


Low noise:

Noise level is decided by the size of power room and level of noise pressure.Reduce the noise to the level corresponding to the environmental noise standard. No need to excessive demands, because this will cause unnecessary high cost.

For many installation, use flexible frame to fix genset, plus the normal control of air exhaust, air inlet and radiator fan, which can reduce the noise to an acceptable level. 

If the noise remain high after these processing, we can set sound insulation board in the room or around the gensets. Fix sound-absorbing board on the wall of the room or put the genset in a special designed sound insulation container to reduce noise.


2.jpg


Hot Tags: 300 KW biogas Generator, China, suppliers, manufacturers, factory
Related Products
Inquiry