Tel: +86-769-88996313

E-mail: sf@camda.cc

80 KW Biogas Generator

Ratings *Ratings at 0.8 power factor Performance Data * The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm 3 Dimensions and Weights Engine Brand & Model: HGT6C Engine Data How to examine the installation of engine: Examine the installation of engine,...

Send Inquiry
Product Details
KDGH80-BG   50HZ1(002).jpg


Ratings

Rated  Power

kVA

100

kW

80

Voltage type

50Hz, 380/220V, 3 phases and 4 wires

*Ratings at 0.8 power factor


Performance Data

Engine Brand & Model

HGT6C

Alternator Brand & Model

LSA44.3S5/80KW

Control System

Deepsea DSE6120

Standard Noise Level@7m (Soundproof Sets)

75 dBA

Circuit Breaker Type

3 Poles MCCB

Frequency & Phase

50hz 3Phases + 4Wires

Engine Speed (RPM)

1500

Fuel Consumption (Nm3/hr) 100% Load

25.14

* The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm3


Dimensions and Weights

Content

Open type

Soundproof Sets

Dimensions: (mm)

L

2450

3200

W

1100

1200

H

1550

1650

Weights (kg)

1150

1835


Engine Brand & Model: HGT6C

Engine Data

No. of Cylinders

6 in-line

Engine power(KW)

176

Cycle

4 Stroke

Cylinder Type

Wet

Bore * Stroke (mm)

114 x 135

Compression Ratio

10.5:1

Induction

Turbocharged

Displacement (L)

8.9

Cooling Method

Water cooled

Governing Type

Electronic

Starting method

24V DC motor

Coolant capacity, engine only (L)

11.1

Lubricant Oil

15W40-CF4 or above grade

Oil pan capacity (L)

27.6


How to examine the installation of engine: 

Examine the installation of engine, whether there is any broken or aging, and examine whether the tightened torque is suitable. The trembling of engine may caused by the reasons as bellow: 

◇The incorrect installation of engine;

◇Examine the base frame of engine is aged or not, if it is, change the base frame.


How to empty the cooling system: 

WARNING: 

◇When the engine temperature is a little high or it still have its pressure, don't take off the cover of coolant, it is very dangerous while the coolant leakage;

◇According to the local lower requiry to treat the scrap coolant;

◇After the genset have stopped, open the cover slowly after the engine had been cooled to depress its pressure, then you can take off the cover completely; 

◇If there is a drainage valve for the cooling system, open it. If not, take off the coolant pipe at the bottom, so that the coolant can leak out from the cooling system.


Exhaust pipe:

The position of engine should be as closer as possible to exhaust pipe, and crook and blockage are smaller.

Normally exhaust pipe is put out of the power room and along the wall up to the roof. Outside the wall, there is a hole sleeve to shock absorption, and a pipe fitting to compensate for expansion of length variation from thermal or cold affect.

Smoke can be exhausted directly into a special flue pipe, which can also be used as an exist of radiator and produce sound insulation effect.

Muffler can be installed in the flue or inside the room with the pipe tail outside. Air orientation should be installed in the flue plates to guide the air from radiator flow up, and reduce the flow resistance of radiator fan, or curved sound insulation pipe.

For the gensets in flat with roof, outdoor independent shelter or mounted on a trailer, the smoke from engine exhaust pipe and radiator exhaust together can flow in campaigned sheiter without a flue. Sometimes, in order to achieve this goal, the level fixed radiator is dricen by aelectric motor fan to emit air vertically. 


2.jpg


Hot Tags: 80 KW biogas Generator, China, suppliers, manufacturers, factory
Related Products
Inquiry