Tel: +86-769-88996313

E-mail: sf@camda.cc

300 KW Gas Generator

300 KW Gas Generator

Ratings *Ratings at 0.8 power factor Performance Data * The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm 3 Dimensions and Weights Engine Brand & Model: HGKT38 Engine Data How to acquire oil samples: Hot oil or components can cause injury. Don’t let...

Send Inquiry
Product Details
KDGH300-NG   50HZ1(001).jpg


Ratings

Rated  Power

kVA

375

kW

300

Voltage type

50Hz, 380/220V, 3 phases and 4 wires

*Ratings at 0.8 power factor


Performance Data

Engine Brand & Model

HGKT19

Alternator Brand & Model

LSA47.2VS2/300KW

Control System

Deepsea DSE6120

Standard Noise Level@7m (Soundproof Sets)

75 dBA

Circuit Breaker Type

3 Poles MCCB

Frequency & Phase

50hz 3Phases + 4Wires

Engine Speed (RPM)

1500

Fuel Consumption (Nm3/hr) 100% Load

86.19

* The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm3


Dimensions and Weights

Content

Open type

Soundproof Sets

Dimensions: (mm)

L

3500

5600

W

1250

2000

H

2020

2500

Weights (kg)

3380

4985


Engine Brand & Model: HGKT19

Engine Data

No. of Cylinders

6 in-line

Engine power(KW)

341

Cycle

4 Stroke

Cylinder Type

Wet

Bore * Stroke (mm)

159 * 159

Compression Ratio

11.5:1

Induction

Turbocharged & Aftercooled

Displacement (L)

18.9

Cooling Method

Water cooled

Governing Type

Electronic

Starting method

24V DC motor

Coolant capacity, including radiator (L)

115

Lubricant Oil

15W40-CF4 or above grade

Oil pan capacity (L)

87


How to acquire oil samples: 

Hot oil or components can cause injury. Don’t let the heat oil or components contact skin. This operation shall be done by trained person.

Get sample by installing a sampling valve. If no sampling valve, please use a vacuum pump along with a long hose. Remove the engine dipstick and insert hose into pipe of dipstick. 

In order to ensure the representative of sample, the sample should be taken when the engine stops after a period of normal running. 

In order to prevent samples being contaminated, the insurance used should be made clean.


How to replace air filter core: 

Air filter cores contain a paper core which can not be cleaned by water. Change it according to the following steps: Loose clip, take off the cover(A1), remove the filter(A2) and discard it; Thoroughly clean the inter shell(A3), replace it with new filter, then tighten the cover; Resetting limit indicator.



Hot Tags: 300 KW gas Generator, China, suppliers, manufacturers, factory
Related Products
Inquiry