KDGH80-NG    50HZ1(001).jpg


Ratings

Rated  Power

kVA

100

kW

80

Voltage type

50Hz,380/220V, 3 phases and 4 wires

*Ratings at 0.8 power factor


Performance Data

Engine Brand & Model

HG6TB

Alternator Brand & Model

LSA44.3S5/80KW

Control System

Deepsea DSE6120

Standard Noise Level@7m (Soundproof Sets)

75 dBA

Circuit Breaker Type

3 Poles MCCB

Frequency & Phase

50hz 3Phases + 4Wires

Engine Speed (RPM)

1500

Fuel Consumption (Nm3/hr)  100% Load

25.14

* The above fuel consumption is calculate with the natural gas whose heat value is 35.8MJ/Nm3


Dimensions and Weights

Content

Open type

Soundproof    Sets

Dimensions: (mm)

L

2450

3200

W

1100

1200

H

1550

1650

Weights (kg)

1150

1835


Engine Brand & Model: HGT6B

Engine Data

No. of Cylinders

6  in-line

Engine power(KW)

100

Cycle

4 Stroke

Cylinder Type

Dry

Bore * Stroke (mm)

102 x120

Compression Ratio

10.5:1

Induction

Turbocharged & Aftercooled

Displacement (L)

5.88

Cooling Method

Water cooled

Governing Type

Electronic

Starting method

24V DC motor

Coolant capacity, including radiator (L)

29.26

Lubricant Oil

15W40-CF4 or above grade

Oil pan capacity (L)

16


Preparation before genset starting:

Before genset starting, check and adjust the whole generator set to keep it in good condition. The connection and fixing of every module must be liable, as well as the gneset's cooling system and electrical starting system to ensure no leaking, no loosing, flexible transfer switch, good lubrication. Gas supply system should be normal, otherwise you have to mend it at once or re-adjust it correctly and then restart it.


All CAMDA supplying gas gensets have been finished the testing. So it can be used with load directly. When it is used for the first time, CAMDA advice its load better to be 80%-90% of full load. When it is for continous usage, please ensure its load to be 75%-80% of full load.

◇clean the dust, water track, oil stain and rust on genset. 

◇check whether all connecting parts and fastening pieces are loose or not; check all moving parts are flexible or not. Is there any part jammed? Check all connecting wires are correct and firm.Check if there is any wire drop off or loosen.

◇Check whether gas intake pipe unobstructed or not.

◇Turn on gas intake pipe switch. 

◇Check whether there is enough oil in oil pan.

◇Whether the cooler is full of coolant or not.

◇Put all the switches on corresponding working position, the air breaker should be placed at "off" position.